T1 - The Influence of Lesion Location on the Diagnostic Accuracy of Adenosine-Free Coronary Pressure Wire Measurements
AU - Kobayashi, Yuhei
AU - Johnson, Nils P.
AU - Berry, Colin
AU - De Bruyne, Bernard
AU - Gould, K. Lance
AU - Jeremias, Allen
AU - Oldroyd, Keith G.
AU - Pijls, Nico H.J.
AU - Fearon, William F.
N1 - Publisher Copyright:
© 2016 American College of Cardiology Foundation
PY - 2016/12/12
Y1 - 2016/12/12
N2 - Objectives This work compares the diagnostic performance of adenosine-free coronary pressure wire indices based on lesion location. Background Several adenosine-free coronary pressure wire indices have been proposed to assess the functional significance of coronary artery lesions; however, there is a theoretical concern that lesion location and the mass of perfused myocardium may affect diagnostic performance. Methods A total of 763 patients were prospectively enrolled from 12 institutions. Fractional flow reserve (FFR) and contrast-based FFR (cFFR) were obtained during adenosine-induced maximal hyperemia and contrast-induced submaximal hyperemia respectively, whereas the instantaneous wave-free ratio (iFR) and distal pressure/aortic pressure (Pd/Pa) were obtained at rest. Using an FFR of ≤0.80 as a reference standard, the diagnostic accuracy of each index was compared based on lesion location (left main or proximal left anterior descending artery [LM/pLAD] compared with other lesion locations). Results The median FFR, cFFR, iFR, and Pd/Pa were 0.81 (interquartile range [IQR]: 0.74 to 0.87), 0.86 (IQR: 0.79 to 0.91), 0.90 (IQR: 0.85 to 0.94), and 0.92 (IQR: 0.88 to 0.95), respectively. The cFFR, iFR, and Pd/Pa were less accurate in LM/pLAD compared with other lesion locations (cFFR: 80.3% vs. 87.8%; iFR: 73.3% vs. 81.8%; Pd/Pa: 71.4% vs. 81.1%, respectively). By receiver-operating characteristics curve analysis, cFFR provided better diagnostic accuracy than resting indices regardless of lesion location (p ≤0.0001 vs. iFR and Pd/Pa for both groups). Conclusions The cFFR, iFR, and Pd/Pa are less accurate in LM/pLAD compared with other lesion locations, likely related to the larger amount of myocardium supplied by LM/pLAD. Nevertheless, cFFR provides the best diagnostic accuracy among the adenosine-free indices, regardless of lesion location.
AB - Objectives This work compares the diagnostic performance of adenosine-free coronary pressure wire indices based on lesion location. Background Several adenosine-free coronary pressure wire indices have been proposed to assess the functional significance of coronary artery lesions; however, there is a theoretical concern that lesion location and the mass of perfused myocardium may affect diagnostic performance. Methods A total of 763 patients were prospectively enrolled from 12 institutions. Fractional flow reserve (FFR) and contrast-based FFR (cFFR) were obtained during adenosine-induced maximal hyperemia and contrast-induced submaximal hyperemia respectively, whereas the instantaneous wave-free ratio (iFR) and distal pressure/aortic pressure (Pd/Pa) were obtained at rest. Using an FFR of ≤0.80 as a reference standard, the diagnostic accuracy of each index was compared based on lesion location (left main or proximal left anterior descending artery [LM/pLAD] compared with other lesion locations). Results The median FFR, cFFR, iFR, and Pd/Pa were 0.81 (interquartile range [IQR]: 0.74 to 0.87), 0.86 (IQR: 0.79 to 0.91), 0.90 (IQR: 0.85 to 0.94), and 0.92 (IQR: 0.88 to 0.95), respectively. The cFFR, iFR, and Pd/Pa were less accurate in LM/pLAD compared with other lesion locations (cFFR: 80.3% vs. 87.8%; iFR: 73.3% vs. 81.8%; Pd/Pa: 71.4% vs. 81.1%, respectively). By receiver-operating characteristics curve analysis, cFFR provided better diagnostic accuracy than resting indices regardless of lesion location (p ≤0.0001 vs. iFR and Pd/Pa for both groups). Conclusions The cFFR, iFR, and Pd/Pa are less accurate in LM/pLAD compared with other lesion locations, likely related to the larger amount of myocardium supplied by LM/pLAD. Nevertheless, cFFR provides the best diagnostic accuracy among the adenosine-free indices, regardless of lesion location.
KW - contrast fractional flow reserve
KW - fractional flow reserve
KW - instantaneous wave-free ratio
UR - http://www.scopus.com/inward/record.url?scp=85001115484&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85001115484&partnerID=8YFLogxK
U2 - 10.1016/j.jcin.2016.08.041
DO - 10.1016/j.jcin.2016.08.041
M3 - Article
C2 - 27838269
AN - SCOPUS:85001115484
SN - 1936-8798
VL - 9
SP - 2390
EP - 2399
JO - JACC: Cardiovascular Interventions
JF - JACC: Cardiovascular Interventions
IS - 23
ER -