TY - JOUR
T1 - Sensitivity and specificity of left ventricular ejection fraction by echocardiographic automated border detection
T2 - Comparison with radionuclide ventriculography
AU - Lucariello, Richard J.
AU - Sun, Ying
AU - Doganay, Guldeniz
AU - Chiaramida, Salvatore A.
N1 - Funding Information:
Received date: 01 August 2008; Revised date: 28 October 2008. * Corresponding author. E-mail: [email protected] Foundation item: Supported by the National Major Fundamental Research Plan “973” Project, China (2007CB209502). Copyright © 2009, Research Institute of Petroleum Exploration and Development, PetroChina. Published by Elsevier BV. All rights reserved.
PY - 1997/11
Y1 - 1997/11
N2 - Background: Echocardiographic automated border detection (ADD) provides on-line, beat-to-beat estimation of left ventricular (LV) ejection fraction (EF). Sensitivity and specificity of using ABD-EF for diagnosing LV dysfunction in routine clinical situations have not been previously studied: Hypothesis: Analysis of ABD-EF data based on receiver operating characteristic (ROC) should provide useful information about sensitivity and specificity for clinical diagnosis of LV function based on ABD-EF. Methods: The study group included 50 consecutive patients with EF measured by both ADD and radionuclide ventriculography (RVG). ABD-EF was recorded for 25 consecutive heart beats in the apical four-chamber view. Data were analyzed statistically by linear regression, Bland-Airman plot, and ROC. In ROC analysis, abnormal LV function was defined RVG-EF ≤ 40%. Results: ADD and RVG showed a moderate correlation in the EF measurements: slope = 0.93, intercept = 17%, r = 0.79 (n = 50). Interbeat variability in ADD was diminished by averaging consecutive beats; standard error of estimate (SEE) decreased from 15.6% without averaging to 12.5% with 25-beat averaging. Bland-Airman analysis indicated that ABD-EF compared unfavorably with RVG-EF with limits of agreement from -11% to 39%. ABD-EF showed a systematic overestimation (p < 0.005), which was compensated by increasing the threshold for abnormal ABD-EF to 56%. With the optimized threshold, ABD-EF provided 89% sensitivity and 89% specificity (85% overall diagnostic accuracy) for diagnosing abnormal LV function. Conclusion: This study explored the limitations of on-line echocardiographic measurement of EF in a clinical setting and provided useful data for assessing interbeat variability, sensitivity, and specificity.
AB - Background: Echocardiographic automated border detection (ADD) provides on-line, beat-to-beat estimation of left ventricular (LV) ejection fraction (EF). Sensitivity and specificity of using ABD-EF for diagnosing LV dysfunction in routine clinical situations have not been previously studied: Hypothesis: Analysis of ABD-EF data based on receiver operating characteristic (ROC) should provide useful information about sensitivity and specificity for clinical diagnosis of LV function based on ABD-EF. Methods: The study group included 50 consecutive patients with EF measured by both ADD and radionuclide ventriculography (RVG). ABD-EF was recorded for 25 consecutive heart beats in the apical four-chamber view. Data were analyzed statistically by linear regression, Bland-Airman plot, and ROC. In ROC analysis, abnormal LV function was defined RVG-EF ≤ 40%. Results: ADD and RVG showed a moderate correlation in the EF measurements: slope = 0.93, intercept = 17%, r = 0.79 (n = 50). Interbeat variability in ADD was diminished by averaging consecutive beats; standard error of estimate (SEE) decreased from 15.6% without averaging to 12.5% with 25-beat averaging. Bland-Airman analysis indicated that ABD-EF compared unfavorably with RVG-EF with limits of agreement from -11% to 39%. ABD-EF showed a systematic overestimation (p < 0.005), which was compensated by increasing the threshold for abnormal ABD-EF to 56%. With the optimized threshold, ABD-EF provided 89% sensitivity and 89% specificity (85% overall diagnostic accuracy) for diagnosing abnormal LV function. Conclusion: This study explored the limitations of on-line echocardiographic measurement of EF in a clinical setting and provided useful data for assessing interbeat variability, sensitivity, and specificity.
KW - Automated border detection
KW - Bland-Altman plot
KW - Echocardiography
KW - Interbeat variability
KW - Receiver operating characteristic
KW - Sensitivity and specificity
UR - http://www.scopus.com/inward/record.url?scp=0030710071&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030710071&partnerID=8YFLogxK
U2 - 10.1002/clc.4960201108
DO - 10.1002/clc.4960201108
M3 - Article
C2 - 9383588
AN - SCOPUS:0030710071
SN - 0160-9289
VL - 20
SP - 943
EP - 948
JO - Clinical Cardiology
JF - Clinical Cardiology
IS - 11
ER -