TY - JOUR
T1 - Preclinical research performed on reanimated/perfused swine kidneys
T2 - The Visible Kidney™ methodologies
AU - Valenzuela, Thomas F.
AU - Schinstock, Emma
AU - Kohnle, Samantha
AU - Latib, Azeem
AU - Bliagos, Dimitrios
AU - Tunev, Stefan
AU - Iaizzo, Paul A.
N1 - Publisher Copyright:
© 2023 The Authors. Physiological Reports published by Wiley Periodicals LLC on behalf of The Physiological Society and the American Physiological Society.
PY - 2023/3
Y1 - 2023/3
N2 - Preclinical research remains the essential platform in the development and optimization of medical therapies and advancements in translational medicines. However, specifically to animal research, federal laws, and institutional policies require investigators to apply the principles of the 3R's (replacement, reduction, and refinement). The concept of benchtop models utilizing isolated organs, in which multiple variables can be controlled to recreate human function, has been innovative advancements in preclinical research models that adhere to these principles. More specifically, isolated perfused kidney (IPK) models have been invaluable preclinical tools that have led to numerous advancements over the decades, including understanding renal physiology, pharmacologic therapies, and improvements in renal transplantation. However, pre-existing IPK models are not without their own limitations, leaving areas for improvement. An isolated perfused kidney apparatus was designed to best recreate human use conditions as a preclinical tool. Porcine renal blocks were chosen over the more commonly used rodent models, due to their greater similarities to human anatomies. Sixteen porcine kidney pairs obtained en bloc were extracted and placed onto an apparatus where aortic flows, pressures, and overall systemic temperatures were controlled. Organ viability was assessed in 10 renal blocks (n = 8 fresh and n = 2 previously frozen specimens) via both urinary flows and compositions at timepoints up to 180 min. Multimodality imaging, which included fluoroscopy, ultrasound, optical coherence tomography (OCT), and video scopes, was also employed to capture internal and external images to determine renal artery orientations and dimensions. Anatomical measurements and viability assessments of porcine renal blocks were successfully achieved in our perfusion model. Renal main artery diameters averaged smaller in our sample size than in human anatomy while also having more superior takeoff angles. Yet, the average lengths of each main segment were comparable to human anatomy: 32.09 ± 7.97 mm and 42.23 ± 7.33 mm in the left and right renal main artery, respectively. Urine production and urine composition of the fresh renal blocks, when compared to the frozen blocks and baseline perfusate, showed kidney viabilities of up to 3 h via excretion and retention of various metabolites. In this paper, we described a protocol for an isolated perfused kidney apparatus using large mammalian renal blocks. We believe this protocol to be an improvement from similar pre-existing models in better representing human physiologic function while allowing for multimodal imaging. The resulting Visible Kidney™ preclinical model, which has shown viability after isolation and reperfusion, can be a fast and reliable tool for the development of medical devices while also reducing the unnecessary use of animals for research.
AB - Preclinical research remains the essential platform in the development and optimization of medical therapies and advancements in translational medicines. However, specifically to animal research, federal laws, and institutional policies require investigators to apply the principles of the 3R's (replacement, reduction, and refinement). The concept of benchtop models utilizing isolated organs, in which multiple variables can be controlled to recreate human function, has been innovative advancements in preclinical research models that adhere to these principles. More specifically, isolated perfused kidney (IPK) models have been invaluable preclinical tools that have led to numerous advancements over the decades, including understanding renal physiology, pharmacologic therapies, and improvements in renal transplantation. However, pre-existing IPK models are not without their own limitations, leaving areas for improvement. An isolated perfused kidney apparatus was designed to best recreate human use conditions as a preclinical tool. Porcine renal blocks were chosen over the more commonly used rodent models, due to their greater similarities to human anatomies. Sixteen porcine kidney pairs obtained en bloc were extracted and placed onto an apparatus where aortic flows, pressures, and overall systemic temperatures were controlled. Organ viability was assessed in 10 renal blocks (n = 8 fresh and n = 2 previously frozen specimens) via both urinary flows and compositions at timepoints up to 180 min. Multimodality imaging, which included fluoroscopy, ultrasound, optical coherence tomography (OCT), and video scopes, was also employed to capture internal and external images to determine renal artery orientations and dimensions. Anatomical measurements and viability assessments of porcine renal blocks were successfully achieved in our perfusion model. Renal main artery diameters averaged smaller in our sample size than in human anatomy while also having more superior takeoff angles. Yet, the average lengths of each main segment were comparable to human anatomy: 32.09 ± 7.97 mm and 42.23 ± 7.33 mm in the left and right renal main artery, respectively. Urine production and urine composition of the fresh renal blocks, when compared to the frozen blocks and baseline perfusate, showed kidney viabilities of up to 3 h via excretion and retention of various metabolites. In this paper, we described a protocol for an isolated perfused kidney apparatus using large mammalian renal blocks. We believe this protocol to be an improvement from similar pre-existing models in better representing human physiologic function while allowing for multimodal imaging. The resulting Visible Kidney™ preclinical model, which has shown viability after isolation and reperfusion, can be a fast and reliable tool for the development of medical devices while also reducing the unnecessary use of animals for research.
UR - http://www.scopus.com/inward/record.url?scp=85149999369&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85149999369&partnerID=8YFLogxK
U2 - 10.14814/phy2.15630
DO - 10.14814/phy2.15630
M3 - Article
C2 - 36878878
AN - SCOPUS:85149999369
SN - 2051-817X
VL - 11
JO - Physiological Reports
JF - Physiological Reports
IS - 5
M1 - e15630
ER -