Outcome of Patients Undergoing Transcatheter Implantation of Aortic Valve With Previous Mitral Valve Prosthesis (OPTIMAL) Study

Luca Baldetti, Francesco Giannini, Nicolas Van Mieghem, N. El Faquir, Didier Tchétché, Chiara De Biase, Anna Sonia Petronio, Cristina Giannini, Giuseppe Tarantini, Chiara Fraccaro, A. Finkelstein, Amit Segev, Israel Barbash, Giuseppe Bruschi, Corrado Tamburino, M. Barbanti, S. Lim, Ivandito Kuntjoro, Mohamed Abdel-Wahab, Antonio ColomboA. Latib

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Background: Transcatheter aortic valve replacement (TAVR) is the gold standard for severe valvular aortic stenosis in patients at high/prohibitive surgical risk. This procedure has also been used in patients with previous mitral valve (MV) prostheses, with contrasting outcomes reported. The aim of this study is to describe procedural and early outcomes of patients with previous MV prostheses undergoing TAVR. Methods: This is a retrospective registry of 154 patients with previous MV prostheses who underwent TAVR across high-volume medical centres at a mean of 11.7 ± 8.4 years after mitral surgery. Results: Mean mitroaortic distance at computed tomography was 9.7 ± 4.8 mm. Procedural success was achieved in 150 (97.4%) patients, with reduction of aortic gradients (42.6 ± 14.2 to 10.0 ± 7.0 mm Hg; P < 0.001). Device success was achieved in 133 (86.3%) patients. MV prosthesis interference by the TAVR device was observed in 2 patients; in both, the mitroaortic distance was <5 mm, with 1 complicated by TAVR prosthesis embolization. Periprocedural complications included 4 (2.6%) cerebrovascular accidents, 10 (6.6%) major vascular complications, 22 (14.4%) severe bleedings, 1 (0.7%) myocardial infarction, and 5 (3.2%) in-hospital deaths (all cases cardiovascular or procedure related). At a median follow-up of 13.5 (interquartile range 1.0 to 36.0) months, 26 (16.9%) deaths occurred; 15 (9.7%) were cardiac related. Late fatal mitral prosthesis thromboses occurred in 2 patients. We recorded a case of fatal hemorrhagic stroke; hospital readmission was observed in 25 (16.2%) patients due to worsening heart failure. Conclusions: TAVR in patients with previous mitral prostheses appears to be safe and feasible, with good hemodynamic results at 30-day and at longer-term follow-up.

Original languageEnglish (US)
Pages (from-to)866-874
Number of pages9
JournalCanadian Journal of Cardiology
Volume35
Issue number7
DOIs
StatePublished - Jul 2019

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Outcome of Patients Undergoing Transcatheter Implantation of Aortic Valve With Previous Mitral Valve Prosthesis (OPTIMAL) Study'. Together they form a unique fingerprint.

Cite this