N2 - Background. The aim of this study is to demonstrate the usefulness of adding 3-dimensional (3D) ultrasound in evaluation of renal transplant vasculature compared to 2-dimensional (2D) Duplex ultrasound. Methods. One hundred thirteen consecutive renal transplant 2D and 3D ultrasound examinations were performed and retrospectively reviewed by 2 board-certified radiologists and a radiology resident individually; each reviewed 2D and then 3D images, including color and spectral Doppler. They recorded ability to visualize the surgical anastomosis and rated visualization on a subjective scale. Interobserver agreement was evaluated. Variant anastomosis anatomy was recorded. Tortuosity or stenosis was evaluated if localized Doppler velocity elevation was present. Results. The reviewers directly visualized the anastomosis more often with 3D ultrasound (x =97.5%) compared with 2D ( x =54.5%) [difference in means (DM) = 43% (95% confidence interval (CI) = 36%-50%) (P < 0.001)]. The reviewers visualized the anastomosis more clearly with 3D ultrasound (P < 0.001) [difference in medians = 0.5, 1.0, and 1.0, (95% CI = 0.5-1.0, 0.5-1.0, and 1.0-1.5)]. Detection of variant anatomy improved with 3D ultrasound by 2 reviewers [DM = 7.1% and 8.9% (95% CI = 1%-13% and 4%-14%, respectively) (P < 0.05)]. There was high interobserver agreement [ x = 95.3%, (95% CI = 91.9%- 98.7%) regarding anastomosis visualization among reviewers with wide-ranging experience. Conclusions. Direct visualization of the entire anastomosis was improved with 3D ultrasound. Three-dimensional evaluation improved detection of anatomic variants and identified tortuosity as the likely cause of borderline localized elevation in Doppler velocity. The data added by 3D ultrasound may obviate confirmatory testing with magnetic resonance angiography or computed tomographic angiography after equivocal 2D ultrasound results.
AB - Background. The aim of this study is to demonstrate the usefulness of adding 3-dimensional (3D) ultrasound in evaluation of renal transplant vasculature compared to 2-dimensional (2D) Duplex ultrasound. Methods. One hundred thirteen consecutive renal transplant 2D and 3D ultrasound examinations were performed and retrospectively reviewed by 2 board-certified radiologists and a radiology resident individually; each reviewed 2D and then 3D images, including color and spectral Doppler. They recorded ability to visualize the surgical anastomosis and rated visualization on a subjective scale. Interobserver agreement was evaluated. Variant anastomosis anatomy was recorded. Tortuosity or stenosis was evaluated if localized Doppler velocity elevation was present. Results. The reviewers directly visualized the anastomosis more often with 3D ultrasound (x =97.5%) compared with 2D ( x =54.5%) [difference in means (DM) = 43% (95% confidence interval (CI) = 36%-50%) (P < 0.001)]. The reviewers visualized the anastomosis more clearly with 3D ultrasound (P < 0.001) [difference in medians = 0.5, 1.0, and 1.0, (95% CI = 0.5-1.0, 0.5-1.0, and 1.0-1.5)]. Detection of variant anatomy improved with 3D ultrasound by 2 reviewers [DM = 7.1% and 8.9% (95% CI = 1%-13% and 4%-14%, respectively) (P < 0.05)]. There was high interobserver agreement [ x = 95.3%, (95% CI = 91.9%- 98.7%) regarding anastomosis visualization among reviewers with wide-ranging experience. Conclusions. Direct visualization of the entire anastomosis was improved with 3D ultrasound. Three-dimensional evaluation improved detection of anatomic variants and identified tortuosity as the likely cause of borderline localized elevation in Doppler velocity. The data added by 3D ultrasound may obviate confirmatory testing with magnetic resonance angiography or computed tomographic angiography after equivocal 2D ultrasound results.
UR - http://www.scopus.com/inward/record.url?scp=85020694145&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85020694145&partnerID=8YFLogxK
U2 - 10.1097/TP.0000000000001206
DO - 10.1097/TP.0000000000001206
M3 - Article
C2 - 28291767
AN - SCOPUS:85020694145
SN - 0041-1337
VL - 101
SP - 1344
EP - 1352
JO - Transplantation
JF - Transplantation
IS - 6
ER -