N2 - Purpose Radiofrequency catheter ablation (RFCA) of supraventricular tachyarrhythmias carries a small but nonnegligible radiation risk. Studies in children already showed the feasibility of using three-dimensional mapping systems as the primary guide for catheter visualization and positioning in these RFCAs. We aim to demonstrate the feasibility and safety of such an approach in young and middle-aged patients. Methods Fifty patients (age 34±12) with supraventricular tachyarrhythmias underwent electrophysiological study; of these, 47 patients proceeded to RFCA guided by the EnSite NavX™ system (23 with atrioventricular nodal reentry tachycardia, 16 with an accessory pathway, six with typical atrial flutter, and two with right atrial tachycardia). Results In 38/50 cases (76%), electroanatomical mapping avoided fluoroscopy entirely, including four cases requiring access to the left heart chambers by a retrograde approach. In the remaining 12/50 cases (24%), fluoroscopy use was limited to 122±80 s, with a correspondingly low radiation exposure (dose area product 1.3±1.1 mGy×m 2). All procedures were acutely successful, with a procedural time of 113±37 minutes, and without incurring in any major complication. Over a mean follow-up of 12±3 months, we observed one recurrence of pre-excitation and one relapse of atrial flutter. Conclusions Our study shows that non-fluoroscopic RFCA of supraventricular tachyarrhythmias using the EnSite NavXTM system is feasible, safe, and effective in a population of relatively young adults. Our experience of a non-fluoroscopic approach in these procedures deserves consideration, particularly in the young or in other patients at higher radiation risk.
AB - Purpose Radiofrequency catheter ablation (RFCA) of supraventricular tachyarrhythmias carries a small but nonnegligible radiation risk. Studies in children already showed the feasibility of using three-dimensional mapping systems as the primary guide for catheter visualization and positioning in these RFCAs. We aim to demonstrate the feasibility and safety of such an approach in young and middle-aged patients. Methods Fifty patients (age 34±12) with supraventricular tachyarrhythmias underwent electrophysiological study; of these, 47 patients proceeded to RFCA guided by the EnSite NavX™ system (23 with atrioventricular nodal reentry tachycardia, 16 with an accessory pathway, six with typical atrial flutter, and two with right atrial tachycardia). Results In 38/50 cases (76%), electroanatomical mapping avoided fluoroscopy entirely, including four cases requiring access to the left heart chambers by a retrograde approach. In the remaining 12/50 cases (24%), fluoroscopy use was limited to 122±80 s, with a correspondingly low radiation exposure (dose area product 1.3±1.1 mGy×m 2). All procedures were acutely successful, with a procedural time of 113±37 minutes, and without incurring in any major complication. Over a mean follow-up of 12±3 months, we observed one recurrence of pre-excitation and one relapse of atrial flutter. Conclusions Our study shows that non-fluoroscopic RFCA of supraventricular tachyarrhythmias using the EnSite NavXTM system is feasible, safe, and effective in a population of relatively young adults. Our experience of a non-fluoroscopic approach in these procedures deserves consideration, particularly in the young or in other patients at higher radiation risk.
KW - Electroanatomical mapping
KW - Radiation exposure
KW - Radiofrequency ablation
KW - Supraventricular arrhythmias
UR - http://www.scopus.com/inward/record.url?scp=80053568738&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80053568738&partnerID=8YFLogxK
U2 - 10.1007/s10840-011-9553-5
DO - 10.1007/s10840-011-9553-5
M3 - Review article
C2 - 21365263
AN - SCOPUS:80053568738
SN - 1383-875X
VL - 31
SP - 109
EP - 118
JO - Journal of Interventional Cardiac Electrophysiology
JF - Journal of Interventional Cardiac Electrophysiology
IS - 2
ER -