Abstract
We report a case of accidental transection of a nasal RAE endotracheal tube (ETT) and subsequent management in a 24-year-old male undergoing maxillary and mandibular osteotomy. Forty-five minutes into the procedure, transection of ETT by the surgical drill resulted in a progressive decrease in tidal volumes and a decline in oxygen saturation. After failing to exchange the ETT over a tube exchanger, a soft suction catheter was threaded through the RAE tube to provide oxygenation and borrow time to re-intubate through the opposite nostril. Suction catheter is a viable tool to maintain oxygenation and mitigate “Cannot Ventilate, Cannot Oxygenate” scenario during accidental transection of ETT.
Original language | English (US) |
---|---|
Pages (from-to) | 33-36 |
Number of pages | 4 |
Journal | Middle East Journal of Anesthesiology |
Volume | 26 |
Issue number | 1 |
State | Published - Feb 2019 |
Keywords
- Airway
- Endotracheal tube
- Nasal intubation
- Suction catheter
ASJC Scopus subject areas
- Anesthesiology and Pain Medicine