TY - JOUR
T1 - Gender differences in clinical outcome and primary prevention defibrillator benefit in patients with severe left ventricular dysfunction
T2 - A systematic review and meta-analysis
AU - Santangeli, Pasquale
AU - Pelargonio, Gemma
AU - Russo, Antonio Dello
AU - Casella, Michela
AU - Bisceglia, Caterina
AU - Bartoletti, Stefano
AU - Santarelli, Pietro
AU - Di Biase, Luigi
AU - Natale, Andrea
N1 - Funding Information:
Dr. Natale has received compensation for belonging to the speakers' bureau for St. Jude Medical, Boston Scientific, Medtronic, and Biosense Webster and has received a research grant from St. Jude Medical .
PY - 2010/7
Y1 - 2010/7
N2 - Background: Women are underrepresented in primary prevention implantable cardioverter-defibrillator (ICD) trials, and data on the benefit of ICD therapy in this subgroup are controversial. Objective: The purpose of this study was to better evaluate the benefit of prophylactic ICD in women by performing a meta-analysis of primary prevention ICD trials that assessed gender differences on the end-points of total mortality, appropriate ICD intervention, and survival benefit of ICD compared with placebo. Methods: PubMed, CENTRAL, and other databases were searched in October 2009. Studies were included only if they examined gender differences in the specified end-points, providing the hazard ratio (HR) obtained in multiple Cox regression analyses, and adjusted for all confounding variables. Results: We retrieved five studies (MADIT-II, MUSTT, SCD-HeFT, DEFINITE, COMPANION) that enrolled 7,229 patients (22% women) with dilated cardiomyopathy (74% ischemic). Compared to men, women had no significant difference in overall mortality (HR 0.96, 95% confidence interval [CI] 0.67-1.39, P = .84) but experienced significantly less appropriate ICD interventions (HR 0.63, 95% CI 0.49-0.82, P ≤.001). The benefit of ICD on mortality was significantly higher in men (HR 0.67, 95% CI 0.58-0.78, P <.001) but did not reach statistical significance in women (HR 0.78, 95% CI 0.57-1.05, P = .1). Conclusion: Women enrolled in primary prevention ICD trials have the same mortality compared to men while experiencing significantly less appropriate ICD interventions, thus suggesting a smaller impact of sudden cardiac death on overall mortality in women with dilated cardiomyopathy. These findings may explain the smaller ICD survival benefit among women.
AB - Background: Women are underrepresented in primary prevention implantable cardioverter-defibrillator (ICD) trials, and data on the benefit of ICD therapy in this subgroup are controversial. Objective: The purpose of this study was to better evaluate the benefit of prophylactic ICD in women by performing a meta-analysis of primary prevention ICD trials that assessed gender differences on the end-points of total mortality, appropriate ICD intervention, and survival benefit of ICD compared with placebo. Methods: PubMed, CENTRAL, and other databases were searched in October 2009. Studies were included only if they examined gender differences in the specified end-points, providing the hazard ratio (HR) obtained in multiple Cox regression analyses, and adjusted for all confounding variables. Results: We retrieved five studies (MADIT-II, MUSTT, SCD-HeFT, DEFINITE, COMPANION) that enrolled 7,229 patients (22% women) with dilated cardiomyopathy (74% ischemic). Compared to men, women had no significant difference in overall mortality (HR 0.96, 95% confidence interval [CI] 0.67-1.39, P = .84) but experienced significantly less appropriate ICD interventions (HR 0.63, 95% CI 0.49-0.82, P ≤.001). The benefit of ICD on mortality was significantly higher in men (HR 0.67, 95% CI 0.58-0.78, P <.001) but did not reach statistical significance in women (HR 0.78, 95% CI 0.57-1.05, P = .1). Conclusion: Women enrolled in primary prevention ICD trials have the same mortality compared to men while experiencing significantly less appropriate ICD interventions, thus suggesting a smaller impact of sudden cardiac death on overall mortality in women with dilated cardiomyopathy. These findings may explain the smaller ICD survival benefit among women.
KW - Dilated cardiomyopathy
KW - Gender differences
KW - Implantable cardioverter-defibrillator
KW - Sudden cardiac death
UR - http://www.scopus.com/inward/record.url?scp=77953917406&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77953917406&partnerID=8YFLogxK
U2 - 10.1016/j.hrthm.2010.03.042
DO - 10.1016/j.hrthm.2010.03.042
M3 - Article
C2 - 20380893
AN - SCOPUS:77953917406
SN - 1547-5271
VL - 7
SP - 876
EP - 882
JO - Heart Rhythm
JF - Heart Rhythm
IS - 7
ER -