Evaluating which plan quality metrics are appropriate for use in lung SBRT

Ravindra Yaparpalvi, Madhur K. Garg, Jin Shen, Willi AM R. Bodner, Dinesh K. Mynampati, Aleiya Gafar, Hsiang Chi Kuo, Amar K. Basavatia, Nitin Ohri, Linda X. Hong, Shalom Kalnicki, Wolfgang A. Tome

Research output: Contribution to journalArticlepeer-review

21 Scopus citations

Abstract

Objective: Several dose metrics in the categories—homogeneity, coverage, conformity and gradient have been proposed in literature for evaluating treatment plan quality. In this study, we applied these metrics to characterize and identify the plan quality metrics that would merit plan quality assessment in lung stereotactic body radiation therapy (SBRT) dose distributions. Methods: Treatment plans of 90 lung SBRT patients, comprising 91 targets, treated in our institution were retrospectively reviewed. Dose calculations were performed using anisotropic analytical algorithm (AAA) with heterogeneity correction. A literature review on published plan quality metrics in the categories—coverage, homogeneity, conformity and gradient was performed. For each patient, using dose-volume histogram data, plan quality metric values were quantified and analysed. Results: For the study, the radiation therapy oncology group (RTOG) defined plan quality metrics were: coverage (0.90 ± 0.08); homogeneity (1.27 ± 0.07); conformity (1.03 ± 0.07) and gradient (4.40 ± 0.80). Geometric conformity strongly correlated with conformity index (p < 0.0001). Gradient measures strongly correlated with target volume (p < 0.0001). The RTOG lung SBRT protocol advocated conformity guidelines for prescribed dose in all categories were met in ≥94% of cases. The proportion of total lung volume receiving doses of 20 Gy and 5 Gy (V20 and V5) were mean 4.8% (±3.2) and 16.4% (±9.2), respectively. Conclusion: Based on our study analyses, we recommend the following metrics as appropriate surrogates for establishing SBRT lung plan quality guidelines—coverage % (ICRU 62), conformity (CN or CIPaddick) and gradient (R50%). Furthermore, we strongly recommend that RTOG lung SBRT protocols adopt either CN or CIPad-ddick in place of prescription isodose to target volume ratio for conformity index evaluation.

Original languageEnglish (US)
Article number20170393
JournalBritish Journal of Radiology
Volume91
Issue number1083
DOIs
StatePublished - 2018

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Evaluating which plan quality metrics are appropriate for use in lung SBRT'. Together they form a unique fingerprint.

Cite this