Effect of focused protocol on reducing radiation dose for children who require computed tomography for suspected appendicitis

Suzanne Roberts, Bernard Goldwasser, Abigail F. Nixon, Deeksha Borkar, Max Brookman, Carolyn E. Fox, Cyril Rosenfeld, James A. Meltzer

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Background: Despite efforts to incorporate ultrasound into the evaluation of children for appendicitis, computed tomography (CT) is often used to aid in its diagnosis. CT scans, however, expose children to a considerable amount of radiation. In 2017, our institution began using a height-based Focused CT protocol for children with suspected appendicitis in need of CT. Objective: To compare the radiation dose received by children with suspected appendicitis who underwent a Standard CT of the abdomen and pelvis (CTAP) with that of a Focused CT. Methods: We conducted a retrospective study of children <18 years who underwent a CT scan for suspected appendicitis (2014–2020). We included all patients whose indication for CT was “appendicitis” or “right lower quadrant pain” and excluded those whose CT scan record lacked a radiation dose report. The effective radiation dose delivered was calculated using the dose-length product from the dose report. We compared the effective dose of those who received a Standard CTAP to those who received a Focused CT. To account for differences in radiation dose over time and by CT scanner, analyses were adjusted for CT dose index volume (CTDIvol) and size-specific dose estimate (SSDE) using quantile regression. Results: A total of 474 patients who underwent CT were included. Prior to CT, 362(76%) had received an ultrasound. In total, 309(65%) patients underwent a Standard CTAP and 165(35%) underwent a Focused CT. The appendix was identified in 259(84%) Standard CTAPs compared to 151(92%) Focused CTs (p = 0.02). Compared to the Standard CTAP, children who received a Focused CT were exposed to a significantly lower effective dose (relative difference: CTDI-adjusted −13%[95% CI:-21,-5]; SSDE-adjusted −14%[95% CI:-24,-3]). Conclusions: Our height-based Focused CT protocol reduces radiation for children undergoing CT evaluation for suspected appendicitis without sacrificing diagnostic accuracy. Further study is needed to validate these findings at other institutions.

Original languageEnglish (US)
Pages (from-to)76-79
Number of pages4
JournalAmerican Journal of Emergency Medicine
Volume50
DOIs
StatePublished - Dec 2021

Keywords

  • Abdominal pain
  • Appendicitis
  • Children
  • Computed tomography
  • Focused
  • Limited
  • Radiation
  • Right lower quadrant

ASJC Scopus subject areas

  • Emergency Medicine

Fingerprint

Dive into the research topics of 'Effect of focused protocol on reducing radiation dose for children who require computed tomography for suspected appendicitis'. Together they form a unique fingerprint.

Cite this