Decreased Utilization of Low Tidal Volume Ventilation Outside of the Intensive Care Unit as Compared to Inside

Luke Andrea, Ari Moskowitz, Jen Ting Chen, Daniel G. Fein

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Investigations into the use of low tidal volume ventilation (LTVV) have been performed for patients in emergency departments (EDs) or intensive care units (ICUs). Practice differences between the ICU and non-ICU care areas have not been described. We hypothesized that the initial implementation of LTVV would be better inside ICUs than outside. Methods: This is a retrospective observational study of patients initiated on invasive mechanical ventilation (IMV) between January 1, 2016, and July 17, 2019. Initial recorded tidal volumes after intubation were used to compare the use of LTVV between care areas. Low tidal volume was considered 6.5 cc/kg of ideal body weight (IBW) or less. The primary outcome was the initiation of low tidal volume. Sensitivity analyses used a tidal volume of 8 cc/kg of IBW or less, and direct comparisons were performed between the ICU, ED, and wards. Results: There were 6392 initiations of IMV: 2217 (34.7%) in the ICU and 4175 (65.3%) outside. LTVV was more likely to be initiated in the ICU than outside (46.5% vs 34.2%; adjusted odds ratio [aOR] 0.62, 95% confidence interval [CI] 0.56-0.71, P <.01). The ICU also had more implementation when PaO2/FiO2 ratio was less than 300, (48.0% vs 34.6%; aOR 0.59, 95% CI 0.48-0.71, P <.01). When comparing individual locations, wards had lower odds of LTVV than the ICU (aOR 0.82, 95% CI 0.70-0.96, P =.02), the ED had lower odds than the ICU (aOR 0.55, 95% CI 0.48-0.63, P <.01), and the ED had lower odds than the wards (aOR 0.66, 95% CI 0.56-0.77, P <.01). Interpretation: Initial low tidal volumes were more likely to be initiated in the ICU than outside. This finding remained when examining only patients with a PaO2/FiO2 ratio less than 300. Care areas outside of the ICU do not employ LTVV as often as ICUs and are, therefore, a possible target for process improvement.

Original languageEnglish (US)
Pages (from-to)949-956
Number of pages8
JournalJournal of Intensive Care Medicine
Volume38
Issue number10
DOIs
StatePublished - Oct 2023

Keywords

  • intensive care unit
  • low tidal volume ventilation
  • respiratory failure

ASJC Scopus subject areas

  • Critical Care and Intensive Care Medicine

Fingerprint

Dive into the research topics of 'Decreased Utilization of Low Tidal Volume Ventilation Outside of the Intensive Care Unit as Compared to Inside'. Together they form a unique fingerprint.

Cite this