TY - JOUR
T1 - Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms
AU - Vivanco-Suarez, Juan
AU - Feigen, Chaim
AU - Javed, Kainaat
AU - Dardick, Joseph M.
AU - Holland, Ryan
AU - Mendez-Ruiz, Alan
AU - Ortega-Gutierrez, Santiago
AU - Haranhalli, Neil
AU - Altschul, David J.
N1 - Funding Information:
We thank Jing Zhang for his assistance with propensity score matching as well as Juan Lin and Jianyou Liu for their input on statistical analysis. This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Publisher Copyright:
© 2022
PY - 2022/6
Y1 - 2022/6
N2 - Flow diversion is an evolving endovascular modality for treating intracranial aneurysms. Although rare, serious adverse events following flow diversion may include ischemic stroke, intracranial hemorrhage, or delayed rupture of the treated aneurysm. This dataset describes 141 flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, or Surpass Streamline on 126 subjects with intracranial aneurysms [1]. The retrospective data were collected from electronic medical records at two large tertiary centers. Baseline patient data included age, sex, and medical comorbidities. The dataset also describes aneurysm characteristics including laterality, anatomic location, morphology, dome height, and neck width. In addition, digital subtraction images showing the internal carotid artery tortuosity were included for aneurysms in the anterior cerebral circulation [2]. Procedural data include case duration, radiation exposure, number of flow diverters deployed, and complications encountered during deployment. In addition, data related to the duration of hospitalization and postoperative adverse events are included. Finally, time to follow up and rates of total aneurysm obliteration at first and second postoperative visits are included. This data is propensity score matching are included. This data is presented as a starting point for future prospective comparisons in the safety and efficacy of flow diverters as more devices become approved and commercially available.
AB - Flow diversion is an evolving endovascular modality for treating intracranial aneurysms. Although rare, serious adverse events following flow diversion may include ischemic stroke, intracranial hemorrhage, or delayed rupture of the treated aneurysm. This dataset describes 141 flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, or Surpass Streamline on 126 subjects with intracranial aneurysms [1]. The retrospective data were collected from electronic medical records at two large tertiary centers. Baseline patient data included age, sex, and medical comorbidities. The dataset also describes aneurysm characteristics including laterality, anatomic location, morphology, dome height, and neck width. In addition, digital subtraction images showing the internal carotid artery tortuosity were included for aneurysms in the anterior cerebral circulation [2]. Procedural data include case duration, radiation exposure, number of flow diverters deployed, and complications encountered during deployment. In addition, data related to the duration of hospitalization and postoperative adverse events are included. Finally, time to follow up and rates of total aneurysm obliteration at first and second postoperative visits are included. This data is propensity score matching are included. This data is presented as a starting point for future prospective comparisons in the safety and efficacy of flow diverters as more devices become approved and commercially available.
KW - Aneurysm
KW - Flow diversion
KW - Pipeline embolization
KW - Stroke
KW - Subarachnoid hemorrhage
UR - http://www.scopus.com/inward/record.url?scp=85131237491&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85131237491&partnerID=8YFLogxK
U2 - 10.1016/j.dib.2022.108299
DO - 10.1016/j.dib.2022.108299
M3 - Article
AN - SCOPUS:85131237491
SN - 2352-3409
VL - 42
JO - Data in Brief
JF - Data in Brief
M1 - 108299
ER -