T1 - Ultrasound-Guided Peripheral Intravenous Catheters to Reduce Central Venous Catheter Use on the Inpatient Medical Ward
AU - Galen, Benjamin T.
AU - Southern, William N.
N1 - Funding Information:
This work was supported by equipment on loan from GE Healthcare.
Publisher Copyright:
© 2018 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2018
Y1 - 2018
N2 - Purpose: The traditional technique of placing a peripheral intravenous (IV) catheter is successful in most cases on inpatient wards. However, when the traditional method fails, a central venous catheter may be placed to maintain IV access. These catheters are associated with risks including central line-associated bloodstream infection. Methods: We evaluated the effectiveness and acceptability of an ultrasound-guided peripheral IV service to reduce the number of newly placed central venous catheters on an inpatient ward. Central venous catheters were counted daily on intervention and control wards using a standard protocol, and rates of newly placed catheters were compared using a Poisson regression model. Nurses were surveyed to assess acceptability and perceived benefit. Results: We found a reduction in the rate of newly placed central venous catheters on the intervention unit compared with the control unit at 90 days: mean 0.47 versus 0.67 newly placed central venous catheters/day, but the difference was not significant (P =.08). Nurses were in favor of the ultrasound-guided IV service, with perceived benefit to their patients. Conclusion: Ultrasound-guided peripheral IV might reduce unnecessary central venous catheters on general inpatient wards. A portable ultrasound used for this purpose was found to be acceptable by nursing staff.
AB - Purpose: The traditional technique of placing a peripheral intravenous (IV) catheter is successful in most cases on inpatient wards. However, when the traditional method fails, a central venous catheter may be placed to maintain IV access. These catheters are associated with risks including central line-associated bloodstream infection. Methods: We evaluated the effectiveness and acceptability of an ultrasound-guided peripheral IV service to reduce the number of newly placed central venous catheters on an inpatient ward. Central venous catheters were counted daily on intervention and control wards using a standard protocol, and rates of newly placed catheters were compared using a Poisson regression model. Nurses were surveyed to assess acceptability and perceived benefit. Results: We found a reduction in the rate of newly placed central venous catheters on the intervention unit compared with the control unit at 90 days: mean 0.47 versus 0.67 newly placed central venous catheters/day, but the difference was not significant (P =.08). Nurses were in favor of the ultrasound-guided IV service, with perceived benefit to their patients. Conclusion: Ultrasound-guided peripheral IV might reduce unnecessary central venous catheters on general inpatient wards. A portable ultrasound used for this purpose was found to be acceptable by nursing staff.
KW - central line-associated bloodstream infection
KW - central venous catheter
KW - ultrasound
KW - ultrasound-guided peripheral IV
UR - http://www.scopus.com/inward/record.url?scp=85040539862&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85040539862&partnerID=8YFLogxK
U2 - 10.1097/QMH.0000000000000156
DO - 10.1097/QMH.0000000000000156
M3 - Article
C2 - 29280905
AN - SCOPUS:85040539862
SN - 1063-8628
VL - 27
SP - 30
EP - 32
JO - Quality management in health care
JF - Quality management in health care
IS - 1
ER -