Abstract
Early spontaneous closure of a fenestration following Fontan palliation may complicate the postoperative management of such patients. The creation of a fenestration in the catheterization laboratory with an intravascular stent may improve these patients' hemodynamic status. The aim of this study is to present a new technique to reduce the diameter of stented Fontan fenestrations in those patients in whom the stent diameter is functionally made too large.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 119-124 |
| Number of pages | 6 |
| Journal | Journal of Interventional Cardiology |
| Volume | 18 |
| Issue number | 2 |
| DOIs | |
| State | Published - Apr 2005 |
| Externally published | Yes |
ASJC Scopus subject areas
- Radiology Nuclear Medicine and imaging
- Cardiology and Cardiovascular Medicine
Fingerprint
Dive into the research topics of '"Taking in the waist": Adjusting the size of a stented Fontan fenestration'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author