Spleen-liver scintiscan: A new technique for distinguishing allograft rejection from cyclosporine nephrotoxicity

  • M. L. Galishoff
  • , S. M. Greenstein
  • , C. Y. Yen
  • , G. S. Lipkowitz
  • , P. Hanson
  • , E. Dunn
  • , J. H. Hong
  • , H. Kaufman
  • , N. A. Solomon
  • , K. M. Butt

Research output: Contribution to journal › Article › peer-review

Abstract

The clinical problem of distinguishing acute renal graft rejection from cyclosporine nephrotoxicity has thus far defied solution. Since graft rejection can be thought of as a local manifestation of a generalized immune response, a test demonstrating increased activity of the immune system should be of great diagnostic value. We propose that quantitative analysis of standard Tc-99m radiocolloid spleen-liver scintiscans in serial fashion can provide an indirect clinical estimate of immune system activity. This paper describes a technique for estimating the radiocolloid distribution from spleen-liver scintiscans in renal transplant patients at multiple intervals postoperatively. Some clinical and investigative implications are explored.

Original languageEnglish (US)
Pages (from-to)1795-1800
Number of pages6
JournalTransplantation proceedings
Volume19
Issue number1 II
StatePublished - 1987
Externally publishedYes

ASJC Scopus subject areas

  • Surgery
  • Transplantation

Fingerprint

Dive into the research topics of 'Spleen-liver scintiscan: A new technique for distinguishing allograft rejection from cyclosporine nephrotoxicity'. Together they form a unique fingerprint.