Skip to main navigation Skip to search Skip to main content

Relative effectiveness of the implantable cardioverter-defibrillator and antiarrhythmic drugs in patients with varying degrees of left ventricular dysfunction who have survived malignant ventricular arrhythmias

  • Michael J. Domanski
  • , Sanjeev Sakseena
  • , Andrew E. Epstein
  • , Alfred P. Hallstrom
  • , Michael A. Brodsky
  • , Soo Kim
  • , Scott Lancaster
  • , Eleanor Schron

Research output: Contribution to journalArticlepeer-review

Abstract

OBJECTIVES: We sought to assess the effect of baseline ejection fraction on survival difference between patients with life-threatening ventricular arrhythmias who were treated with an antiarrhythmic drug (AAD) or implantable cardioverter-defibrillator (ICD). BACKGROUND: The Antiarrhythmics Versus Implantable Defibrillators (AVID) study demonstrated improved survival in patients with ventricular fibrillation or ventricular tachycardia with a left ventricular ejection fraction (LVEF) ≤0.40 or hemodynamic compromise. METHODS: Survival differences between AAD-treated and ICD-treated patients entered into the AVID study (patients presenting with sustained ventricular arrhythmia associated with an LVEF ≤0.40 or hemodynamic compromise) were compared at different levels of ejection fraction. RESULTS: In patients with an LVEF ≥0.35, there was no difference in survival between AAD-treated and ICD-treated patients. A test for interaction was not significant, but had low power to detect an interaction. For patients with an LVEF 0.20 to 0.34, there was a significantly improved survival with ICD as compared with AAD therapy. In the smaller subgroup with an LVEF <0.20, the same magnitude of survival difference was seen as that in the 0.20 to 0.34 LVEF subgroup, but the difference did not reach statistical significance. CONCLUSIONS: These data suggest that patients with relatively well-preserved LVEF (≥0.35) may not have better survival when treated with the ICD as compared with AADs. At a lower LVEF, the ICD appears to offer improved survival as compared with AADs. Prospective studies with larger patient numbers are needed to assess the effect of relatively well-preserved ejection fraction (≥0.35) on the relative treatment effect of AADs and the ICDs.

Original languageEnglish (US)
Pages (from-to)1090-1095
Number of pages6
JournalJournal of the American College of Cardiology
Volume34
Issue number4
DOIs
StatePublished - Oct 1999

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Relative effectiveness of the implantable cardioverter-defibrillator and antiarrhythmic drugs in patients with varying degrees of left ventricular dysfunction who have survived malignant ventricular arrhythmias'. Together they form a unique fingerprint.

Cite this