T1 - Precision and accuracy of an artificial anterior chamber system in obtaining corneal lenticules for lamellar keratoplasty
AU - Behrens, Ashley
AU - Dolorico, Arlene M.T.
AU - Kara, David T.
AU - Novick, Lee H.
AU - McDonnell, Peter J.
AU - Chao, Lawrence C.
AU - Wellik, Sarah R.
AU - Chuck, Roy S.
N1 - Funding Information:
Supported by grants from the Pan-American Association of Ophthalmology (Behrens) and the Dumont Foundation (McDonnell).
PY - 2001
Y1 - 2001
N2 - Purpose: To determine the precision and accuracy of an artificial anterior chamber and a manual microkeratome in obtaining corneal lenticules for lamellar keratoplasty. Setting: Department of Ophthalmology, Cornea, External Diseases and Refractive Surgery Service, University of California Irvine, Irvine, California, USA. Methods: A lamellar keratectomy was performed in 47 human corneoscleral rims. Three lenticule thicknesses (180, 300, and 360 μm heads) and 3 diameters (7.0, 8.0, and 9.0 mm) were attempted. Diameters and thicknesses were measured by planimetry and pachymetry, respectively. Results: Peripheral lenticule thickness was more likely to be within ±50 μm of the intended depth in thinner cuts (180 μm, 9/15 corneas, 60%; 300 μm, 6/16 corneas, 40%; 360 μm, 3/12 corneas, 33.3%) (P = .045). Eighty percent (32/40 corneas) were within ± 0.5 mm of the expected diameter. Accuracy was best in the 8.0 mm group, with 47.1% (8/17 corneas) within ± 0.2 mm of the expected diameter. A thickness/diameter correlation was not observed (rs ≤ 0.28). Conclusions: The precision and accuracy of this system varied according to the attempted thickness and diameter.
AB - Purpose: To determine the precision and accuracy of an artificial anterior chamber and a manual microkeratome in obtaining corneal lenticules for lamellar keratoplasty. Setting: Department of Ophthalmology, Cornea, External Diseases and Refractive Surgery Service, University of California Irvine, Irvine, California, USA. Methods: A lamellar keratectomy was performed in 47 human corneoscleral rims. Three lenticule thicknesses (180, 300, and 360 μm heads) and 3 diameters (7.0, 8.0, and 9.0 mm) were attempted. Diameters and thicknesses were measured by planimetry and pachymetry, respectively. Results: Peripheral lenticule thickness was more likely to be within ±50 μm of the intended depth in thinner cuts (180 μm, 9/15 corneas, 60%; 300 μm, 6/16 corneas, 40%; 360 μm, 3/12 corneas, 33.3%) (P = .045). Eighty percent (32/40 corneas) were within ± 0.5 mm of the expected diameter. Accuracy was best in the 8.0 mm group, with 47.1% (8/17 corneas) within ± 0.2 mm of the expected diameter. A thickness/diameter correlation was not observed (rs ≤ 0.28). Conclusions: The precision and accuracy of this system varied according to the attempted thickness and diameter.
UR - http://www.scopus.com/inward/record.url?scp=0034749721&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034749721&partnerID=8YFLogxK
U2 - 10.1016/S0886-3350(01)00896-3
DO - 10.1016/S0886-3350(01)00896-3
M3 - Article
C2 - 11687370
AN - SCOPUS:0034749721
SN - 0886-3350
VL - 27
SP - 1679
EP - 1687
JO - Journal of cataract and refractive surgery
JF - Journal of cataract and refractive surgery
IS - 10
ER -