Skip to main navigation Skip to search Skip to main content

Periprocedural and short-term outcomes of transfemoral transcatheter aortic valve implantation with the Sapien XT as compared with the Edwards Sapien valve

  • Marco Mussardo
  • , Azeem Latib
  • , Alaide Chieffo
  • , Cosmo Godino
  • , Alfonso Ielasi
  • , Micaela Cioni
  • , Kensuke Takagi
  • , Giedrius Davidavicius
  • , Matteo Montorfano
  • , Francesco Maisano
  • , Mauro Carlino
  • , Annalisa Franco
  • , Remo D. Covello
  • , Pietro Spagnolo
  • , Antonio Grimaldi
  • , Ottavio Alfieri
  • , Antonio Colombo

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: The aim of this study was to analyze the short-term outcomes after transcatheter aortic valve implantation with the Edwards Sapien THV (ESV), compared with the Sapien XT THV (SXT) (Edwards Lifesciences, Irvine, California). Background: The SXT has been recently commercialized in Europe, but there are no studies analyzing the efficacy and safety of SXT, compared with ESV. Methods: All consecutive patients (n = 120) who underwent transcatheter aortic valve implantation in our center via the transfemoral approach with either ESV (n = 66) or SXT (n = 54). Valve Academic Research Consortium endpoints were used. Results: Mean age was 80 ± 8 years, and mean Logistic-European System for Cardiac Operative Risk Evaluation was 24.9 ± 17.0. The ilio-femoral artery minimal lumen diameter was smaller in patients treated with the SXT (7.27 ± 1.09 mm vs. 7.94 ± 1.08 mm, p = 0.002). Device success was high in both groups (96.3% vs. 92.4%, p = 0.45). Major vascular events were 3-fold lower in the SXT group (11.1% vs. 33.3%, relative risk: 0.40, 95% confidence interval: 0.28 to 0.57; p = 0.004). Life-threatening and major bleeding events were not significantly different between groups (18.5% vs. 27.3% and 35.2% vs. 40.9%, respectively). The SXT group had a lower 30-day Valve Academic Research Consortium combined safety endpoint (20.4% vs. 45.5%; relative risk: 0.44, 95% confidence interval: 0.24 to 0.80; p = 0.004). The 30-day mortality was 1.7% (n = 2). At 30 days, mean transaortic gradient was approximately 10 mm Hg in both groups and the aortic regurgitation was mild-to-moderate in 70.2% of SXT and 76.3% of ESV. Conclusions: The new SXT valve has the same short-term performance as the ESV but seems to be associated with a lower risk of major vascular complications and thus has a broader clinical application.

Original languageEnglish (US)
Pages (from-to)743-750
Number of pages8
JournalJACC: Cardiovascular Interventions
Volume4
Issue number7
DOIs
StatePublished - Jul 2011
Externally publishedYes

Keywords

  • aortic stenosis
  • aortic valve replacement
  • transcatheter aortic valve implantation (TAVI)

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Periprocedural and short-term outcomes of transfemoral transcatheter aortic valve implantation with the Sapien XT as compared with the Edwards Sapien valve'. Together they form a unique fingerprint.

Cite this