TY - JOUR
T1 - Outcomes of glued foldable intraocular lens implantation in eyes with preexisting complications and combined surgical procedures
AU - Kang, Joann J.
AU - Ritterband, David C.
AU - Tolees, Sherif S.
AU - Seedor, John A.
N1 - Publisher Copyright:
© 2015 ASCRS and ESCRS.
PY - 2015
Y1 - 2015
N2 - Purpose To evaluate the visual outcomes and complications of glued foldable intraocular lens (IOL) implantation in patients with a wide range of ocular pathologies and/or having combined surgical procedures. Setting New York Eye and Ear Infirmary of Mount Sinai, New York, New York, USA. Design Retrospective case series. Methods A chart review was conducted of all glued foldable IOL procedures performed in eyes with absent or insufficient capsule support. Patients with a postoperative follow-up less than 3 months were excluded from analysis. Intraoperative and postoperative complications, the postoperative course, and visual and refractive outcomes were analyzed. Results Sixty-five eyes (64 patients) were evaluated over a mean follow-up of 9.1 months ± 6.2 (SD). Ocular comorbidities were present in 98.5% of eyes, and 95.4% had additional concurrent surgical procedures. There was a statistically significant improvement in corrected distance visual acuity (P =.046), with 89.2% of eyes achieving better or equal vision postoperatively. Intraoperative complications included ocular hemorrhage (10.8%), haptic deformation (10.8%), and haptic breakage (1.5%). Postoperative complications included elevated intraocular pressure (13.8%), optic capture (12.3%), persistent anterior chamber inflammation (6.2%), IOL tilt (4.6%), cystoid macular edema (3.1%), recurrent ocular hemorrhage (3.1%), and retinal detachment (1.5%). Conclusion The glued foldable IOL technique resulted in favorable visual outcomes but with a moderate risk for IOL-related and other postoperative complications in eyes with complex ocular comorbidities having combined surgical procedures. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
AB - Purpose To evaluate the visual outcomes and complications of glued foldable intraocular lens (IOL) implantation in patients with a wide range of ocular pathologies and/or having combined surgical procedures. Setting New York Eye and Ear Infirmary of Mount Sinai, New York, New York, USA. Design Retrospective case series. Methods A chart review was conducted of all glued foldable IOL procedures performed in eyes with absent or insufficient capsule support. Patients with a postoperative follow-up less than 3 months were excluded from analysis. Intraoperative and postoperative complications, the postoperative course, and visual and refractive outcomes were analyzed. Results Sixty-five eyes (64 patients) were evaluated over a mean follow-up of 9.1 months ± 6.2 (SD). Ocular comorbidities were present in 98.5% of eyes, and 95.4% had additional concurrent surgical procedures. There was a statistically significant improvement in corrected distance visual acuity (P =.046), with 89.2% of eyes achieving better or equal vision postoperatively. Intraoperative complications included ocular hemorrhage (10.8%), haptic deformation (10.8%), and haptic breakage (1.5%). Postoperative complications included elevated intraocular pressure (13.8%), optic capture (12.3%), persistent anterior chamber inflammation (6.2%), IOL tilt (4.6%), cystoid macular edema (3.1%), recurrent ocular hemorrhage (3.1%), and retinal detachment (1.5%). Conclusion The glued foldable IOL technique resulted in favorable visual outcomes but with a moderate risk for IOL-related and other postoperative complications in eyes with complex ocular comorbidities having combined surgical procedures. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
UR - http://www.scopus.com/inward/record.url?scp=84962300411&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84962300411&partnerID=8YFLogxK
U2 - 10.1016/j.jcrs.2015.10.006
DO - 10.1016/j.jcrs.2015.10.006
M3 - Article
C2 - 26603392
AN - SCOPUS:84962300411
SN - 0886-3350
VL - 41
SP - 1839
EP - 1844
JO - Journal of Cataract and Refractive Surgery
JF - Journal of Cataract and Refractive Surgery
IS - 9
ER -