TY - JOUR
T1 - Outcomes of Descemet Stripping Endothelial Keratoplasty in Eyes with Pars Plana Versus Anterior Chamber Glaucoma Drainage Devices
AU - Kang, Joann J.
AU - Rittterband, David C.
AU - Lai, Kevin
AU - Eisenberg, Ruth E.
AU - Liebmann, Jeffrey M.
AU - Seedor, John A.
N1 - Funding Information:
Supported by Research to Prevent Blindness, New York, NY.
Publisher Copyright:
© 2019 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2019/11/1
Y1 - 2019/11/1
N2 - Purpose:To compare visual outcomes and complications of Descemet stripping endothelial keratoplasty (DSEK) in eyes with anterior chamber (AC) versus pars plana (PP) glaucoma drainage devices (GDDs).Methods:A retrospective chart review was conducted of 85 eyes that underwent DSEK and had previous or concurrent AC (37 eyes) or PP (48 eyes) GDD implantation. Outcome measures examined included visual acuity, donor dislocation rate, intraocular pressure, and secondary graft failure (SGF).Results:The mean logarithm of the minimum angle of resolution vision improved from 1.50 (SD = 0.64) to 0.88 (SD = 0.71) in the AC group and from 1.37 (SD = 0.59) to 1.20 (SD = 0.76) in the PP group, with no significant group difference. Intraocular pressure did not differ between the groups preoperatively but was higher in the AC group compared with the PP group postoperatively [mean (SD) 14.5 (6.28) versus 11.5 (5.54) mm Hg, P = 0.03]. Graft dislocation occurred in 35.1% and 29.2% of eyes in the AC and PP groups, respectively. SGF occurred in 18.9% and 41.7% with median time 17.1 (interquartile range [IQR] 4.6-32.1) and 27.9 (IQR 15.1-34.7) months to development in the AC and PP groups, respectively. Multivariable logistic and Cox proportional hazards regression models found no statistically significant factors (tube location, age, sex, concurrent tube revision, new tube insertion) associated with either donor dislocation or SGF.Conclusions:There was no reduction in donor dislocation or SGF in eyes with PP compared with AC GDD, despite the decreased proximity of the shunt from the endothelial graft. Overall, GDD has a significantly adverse effect on long-term graft survival and close follow-up is warranted.
AB - Purpose:To compare visual outcomes and complications of Descemet stripping endothelial keratoplasty (DSEK) in eyes with anterior chamber (AC) versus pars plana (PP) glaucoma drainage devices (GDDs).Methods:A retrospective chart review was conducted of 85 eyes that underwent DSEK and had previous or concurrent AC (37 eyes) or PP (48 eyes) GDD implantation. Outcome measures examined included visual acuity, donor dislocation rate, intraocular pressure, and secondary graft failure (SGF).Results:The mean logarithm of the minimum angle of resolution vision improved from 1.50 (SD = 0.64) to 0.88 (SD = 0.71) in the AC group and from 1.37 (SD = 0.59) to 1.20 (SD = 0.76) in the PP group, with no significant group difference. Intraocular pressure did not differ between the groups preoperatively but was higher in the AC group compared with the PP group postoperatively [mean (SD) 14.5 (6.28) versus 11.5 (5.54) mm Hg, P = 0.03]. Graft dislocation occurred in 35.1% and 29.2% of eyes in the AC and PP groups, respectively. SGF occurred in 18.9% and 41.7% with median time 17.1 (interquartile range [IQR] 4.6-32.1) and 27.9 (IQR 15.1-34.7) months to development in the AC and PP groups, respectively. Multivariable logistic and Cox proportional hazards regression models found no statistically significant factors (tube location, age, sex, concurrent tube revision, new tube insertion) associated with either donor dislocation or SGF.Conclusions:There was no reduction in donor dislocation or SGF in eyes with PP compared with AC GDD, despite the decreased proximity of the shunt from the endothelial graft. Overall, GDD has a significantly adverse effect on long-term graft survival and close follow-up is warranted.
KW - DSEK
KW - anterior chamber GDD
KW - glaucoma
KW - graft failure
KW - pars plana GDD
UR - http://www.scopus.com/inward/record.url?scp=85072849241&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85072849241&partnerID=8YFLogxK
U2 - 10.1097/ICO.0000000000002059
DO - 10.1097/ICO.0000000000002059
M3 - Article
C2 - 31335528
AN - SCOPUS:85072849241
SN - 0277-3740
VL - 38
SP - 1364
EP - 1369
JO - Cornea
JF - Cornea
IS - 11
ER -