TY - JOUR
T1 - Independent volumetric internal fixation reduces posterior column acetabular fracture site motion as compared to plate/screw construct
T2 - A biomechanical analysis
AU - Fraser, Helyn G.
AU - Honeycutt, M. Wesley
AU - Thompson, Daniel
AU - Suh, Nina
AU - Phen, Huai Ming
AU - Godfrey, William S.
AU - Boissoneault, Adam R.
AU - Maceroli, Michael A.
N1 - Publisher Copyright:
© 2024 Professor P K Surendran Memorial Education Foundation
PY - 2025/1
Y1 - 2025/1
N2 - Aims & objectives: To establish whether a suprapectineal pelvic reconstruction plate and posterior column screw (P&S) construct or a single 6.5-mm cannulated posterior column screw (PCS) construct demonstrates greater mechanical stability for fixation of acetabulum fractures involving the posterior column (PC). We hypothesized that the PCS construct would result in less fracture site motion. Materials & methods: Twelve fourth-generation composite hemipelvi were utilized, 6 for each construct. The P&S construct consisted of a suprapectineal pelvic reconstruction plate with two 3.5-mm posterior column screws crossing the fracture site in lag-by-technique fashion and two screws anchoring the plate to the sciatic buttress. The PCS construct consisted of a single 6.5-mm partially threaded cannulated screw placed in an antegrade fashion. Both fixation models were cyclically loaded at 0.5 cycles/second at 400N and 800N, first in a sit-to-stand position that is expected during recovery, and subsequently in a squat-to-stand position to test overload conditions. Results: Under sit-to-stand loading, the PCS construct resulted in less motion at the fracture site than the P&S construct (0.06 ± 0.02 mm vs 0.1 ± 0.02 mm at 400N, p = 0.02; 0.13 ± 0.03 mm vs 0.19 ± 0.04 mm at 800N, p = 0.03). The PCS construct also demonstrated less fracture site motion under squat-to-stand loading (0.22 ± 0.13 mm vs 1.9 ± 0.5 mm at 400N, p = < 0.001; 1.48 ± 0.44 mm vs 4.77 ± 0.3 mm at 800N, p = < 0.001). At 800 N, half of the repairs failed during squat-to-stand loading (2 PCS, 4 P&S). Conclusion: Fixation of the posterior column of the acetabulum with a 6.5-mm cannulated screw demonstrated comparable fracture motion upon loading compared to the plate and screw construct.
AB - Aims & objectives: To establish whether a suprapectineal pelvic reconstruction plate and posterior column screw (P&S) construct or a single 6.5-mm cannulated posterior column screw (PCS) construct demonstrates greater mechanical stability for fixation of acetabulum fractures involving the posterior column (PC). We hypothesized that the PCS construct would result in less fracture site motion. Materials & methods: Twelve fourth-generation composite hemipelvi were utilized, 6 for each construct. The P&S construct consisted of a suprapectineal pelvic reconstruction plate with two 3.5-mm posterior column screws crossing the fracture site in lag-by-technique fashion and two screws anchoring the plate to the sciatic buttress. The PCS construct consisted of a single 6.5-mm partially threaded cannulated screw placed in an antegrade fashion. Both fixation models were cyclically loaded at 0.5 cycles/second at 400N and 800N, first in a sit-to-stand position that is expected during recovery, and subsequently in a squat-to-stand position to test overload conditions. Results: Under sit-to-stand loading, the PCS construct resulted in less motion at the fracture site than the P&S construct (0.06 ± 0.02 mm vs 0.1 ± 0.02 mm at 400N, p = 0.02; 0.13 ± 0.03 mm vs 0.19 ± 0.04 mm at 800N, p = 0.03). The PCS construct also demonstrated less fracture site motion under squat-to-stand loading (0.22 ± 0.13 mm vs 1.9 ± 0.5 mm at 400N, p = < 0.001; 1.48 ± 0.44 mm vs 4.77 ± 0.3 mm at 800N, p = < 0.001). At 800 N, half of the repairs failed during squat-to-stand loading (2 PCS, 4 P&S). Conclusion: Fixation of the posterior column of the acetabulum with a 6.5-mm cannulated screw demonstrated comparable fracture motion upon loading compared to the plate and screw construct.
KW - Acetabulum fracture
KW - Biomechanics
KW - Cannulated screw
KW - Pelvic reconstruction plate
KW - Posterior column
UR - http://www.scopus.com/inward/record.url?scp=85204206221&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85204206221&partnerID=8YFLogxK
U2 - 10.1016/j.jor.2024.07.007
DO - 10.1016/j.jor.2024.07.007
M3 - Article
AN - SCOPUS:85204206221
SN - 0972-978X
VL - 59
SP - 1
EP - 7
JO - Journal of Orthopaedics
JF - Journal of Orthopaedics
ER -