Independent volumetric internal fixation reduces posterior column acetabular fracture site motion as compared to plate/screw construct: A biomechanical analysis

Helyn G. Fraser, M. Wesley Honeycutt, Daniel Thompson, Nina Suh, Huai Ming Phen, William S. Godfrey, Adam R. Boissoneault, Michael A. Maceroli

Research output: Contribution to journalArticlepeer-review

Abstract

Aims & objectives: To establish whether a suprapectineal pelvic reconstruction plate and posterior column screw (P&S) construct or a single 6.5-mm cannulated posterior column screw (PCS) construct demonstrates greater mechanical stability for fixation of acetabulum fractures involving the posterior column (PC). We hypothesized that the PCS construct would result in less fracture site motion. Materials & methods: Twelve fourth-generation composite hemipelvi were utilized, 6 for each construct. The P&S construct consisted of a suprapectineal pelvic reconstruction plate with two 3.5-mm posterior column screws crossing the fracture site in lag-by-technique fashion and two screws anchoring the plate to the sciatic buttress. The PCS construct consisted of a single 6.5-mm partially threaded cannulated screw placed in an antegrade fashion. Both fixation models were cyclically loaded at 0.5 cycles/second at 400N and 800N, first in a sit-to-stand position that is expected during recovery, and subsequently in a squat-to-stand position to test overload conditions. Results: Under sit-to-stand loading, the PCS construct resulted in less motion at the fracture site than the P&S construct (0.06 ± 0.02 mm vs 0.1 ± 0.02 mm at 400N, p = 0.02; 0.13 ± 0.03 mm vs 0.19 ± 0.04 mm at 800N, p = 0.03). The PCS construct also demonstrated less fracture site motion under squat-to-stand loading (0.22 ± 0.13 mm vs 1.9 ± 0.5 mm at 400N, p = < 0.001; 1.48 ± 0.44 mm vs 4.77 ± 0.3 mm at 800N, p = < 0.001). At 800 N, half of the repairs failed during squat-to-stand loading (2 PCS, 4 P&S). Conclusion: Fixation of the posterior column of the acetabulum with a 6.5-mm cannulated screw demonstrated comparable fracture motion upon loading compared to the plate and screw construct.

Original languageEnglish (US)
Pages (from-to)1-7
Number of pages7
JournalJournal of Orthopaedics
Volume59
DOIs
StatePublished - Jan 2025

Keywords

  • Acetabulum fracture
  • Biomechanics
  • Cannulated screw
  • Pelvic reconstruction plate
  • Posterior column

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Fingerprint

Dive into the research topics of 'Independent volumetric internal fixation reduces posterior column acetabular fracture site motion as compared to plate/screw construct: A biomechanical analysis'. Together they form a unique fingerprint.

Cite this