Skip to main navigation Skip to search Skip to main content

Hospitalization rates and associated cost analysis of cardiac resynchronization therapy with an implantable defibrillator and quadripolar vs. bipolar left ventricular leads: A comparative effectiveness study

  • Giovanni B. Forleo
  • , Luigi Di Biase
  • , Rupinder Bharmi
  • , Nirav Dalal
  • , Germana Panattoni
  • , Annalisa Pollastrelli
  • , Manfredi Tesauro
  • , Luca Santini
  • , Andrea Natale
  • , Francesco Romeo

Research output: Contribution to journalArticlepeer-review

Abstract

Aims This study compares, from a prospective, observational, non-randomized registry, the post-implant hospitalization rates and associated healthcare resource utilization of cardiac resynchronization therapy-defibrillator (CRT-D) patients with quadripolar (QUAD) vs. bipolar (BIP) left ventricular (LV) leads. Methods and results Between January 2009 and December 2012, 193 consecutive patients receiving de novo CRT-D implants with either a QUAD (n = 116) or a BIP (n = 77) LV lead were enrolled at implant and followed until July 2013 at a single-centre, university hospital. Post-implant hospitalizations related to heart failure (HF) or LV lead surgical revision and associated payer costs were identified using ICD-9-CM diagnosis and procedure codes. Italian national reimbursement rates were determined. Propensity scores were estimated using a logistic regression model based upon 11 pre-implant baseline characteristics and were used to derive a 1: 1 matched cohort of QUAD (n = 77) and BIP (n = 77) patients. Hospitalization rates for the two groups were compared using negative binomial regression and associated payer costs were compared using non-parametric bootstrapping (×10 000) and one-sided hypothesis test. Hospitalization rates of the QUAD group [0.15/ patient (pt)-year] were lower than those of the BIP group (0.32/ pt-year); the incidence rate ratio was 0.46, P = 0.04. The hospitalization costs for the QUAD group (434 ± 128 €/pt-year) were lower than those for the BIP group (1136 ± 362 €/pt-year). The average difference was 718 €/pt-year, P = 0.016. Conclusions In this comparative effectiveness assessment of well-matched groups of CRT-D patients with quadripolar and bipolar LV leads, QUAD patients experienced a lower rate of hospitalizations for HF and LV lead surgical revision, and a lower cost burden. This has important implications for LV pacing lead choice.

Original languageEnglish (US)
Pages (from-to)101-107
Number of pages7
JournalEuropace
Volume17
Issue number1
DOIs
StatePublished - Nov 25 2014

Keywords

  • Cardiac resynchronization therapy
  • Cost-effectiveness
  • Health economics
  • Hospitalizations
  • Left ventricular lead
  • Quadripolar lead

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)