Skip to main navigation Skip to search Skip to main content

Bioresorbable vascular scaffold versus everolimus-eluting stents or drug eluting balloon for the treatment of coronary in-stent restenosis: 1-Year follow-up of a propensity score matching comparison (the BIORESOLVE-ISR Study)

  • Elisabetta Moscarella
  • , Akihito Tanaka
  • , Alfonso Ielasi
  • , Bernardo Cortese
  • , Sebastian Coscarelli
  • , Maria Carmen De Angelis
  • , Davide Piraino
  • , Azeem Latib
  • , Giulietta Grigis
  • , Renatomaria Bianchi
  • , Dario Buccheri
  • , Paolo Calabrò
  • , Maurizio Tespili
  • , Pedro Silva Orrego
  • , Antonio Colombo
  • , Attilio Varricchio

Research output: Contribution to journal › Article › peer-review

Abstract

Objectives: to compare the 1-year outcome between bioresorbable vascular scaffold (BVS), everolimus-eluting stent (EES), and drug-eluting balloon (DEB) for in-stent restenosis (ISR) treatment. Background: BVS has been proposed as alternative for ISR treatment. To date a direct comparison between BVS and DES or DEB for ISR treatment is lacking. Methods: We retrospectively analyzed all ISR lesions treated with BVS, DEB, and EES from January 2012 to December 2014. A total of 548 lesions (498 patients) were included. By applying two propensity-score matching, 93 lesions treated with BVS were compared with 93 lesions treated with DEB, and 100 lesions treated with BVS were compared to 100 lesions treated with EES. Results: At 1-year follow-up the incidence of device-oriented cardiovascular events (DOCE) and its components did not significantly differ between BVS and DEB (DOCE: 10.9 vs. 11.8%, HR, 0.91; 95% CI, 0.33–2.52; P = 0.86; Cardiac death: 2.2 vs. 1.2%, HR, 1.74, 95% CI 0.16–18.80, P = 0.65; ID-TLR: 8.9 vs. 10.7%, HR, 0.81, 95% CI 0.27–2.48, P = 0.71; TV-MI: 3.3 vs. 1.2%, HR, 2.39, 95% CI 0.27–21.32, P = 0.43) and BVS vs. EES (DOCE: 10.1 vs. 5.2% HR, 1.81, 95% CI, 0.63–5.25; P = 0.27; Cardiac death: 3.0 vs. 1.1%; HR, 2.83, 95% CI 0.29–27.4, P = 0.37; ID-TLR: 7.2 vs. 4.2%, HR, 1.57, 95% CI 0.47–5.23, P = 0.46; TV-MI: 3.1 vs. 0%). Conclusion: At 1-year follow-up the use of BVS as ISR treatment is associated with a higher, even if not significant, DOCE rate compared with EES while a similar rate compared to DEB.

Original languageEnglish (US)
Pages (from-to)668-677
Number of pages10
JournalCatheterization and Cardiovascular Interventions
Volume92
Issue number4
DOIs
StatePublished - Oct 1 2018
Externally publishedYes

Keywords

  • bioresorbable vascular scaffold
  • drug eluting balloon
  • drug eluting stent
  • in stent restenosis
  • percutaneous coronary intervention

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Bioresorbable vascular scaffold versus everolimus-eluting stents or drug eluting balloon for the treatment of coronary in-stent restenosis: 1-Year follow-up of a propensity score matching comparison (the BIORESOLVE-ISR Study)'. Together they form a unique fingerprint.

Cite this