Bilateral branch pulmonary artery valve implantation in repaired tetralogy of fallot

Neha Bansal, Daisuke Kobayashi, Thomas J. Forbes, Wei Du, Jeffrey M. Zerin, Aparna Joshi, Daniel R. Turner

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Background: Transcatheter, bilateral branch pulmonary artery (PA) valve implantation is a novel treatment for patients with severe pulmonary insufficiency and oversized right ventricle (RV) outflow tract. There is scarce data on efficacy and safety of this approach. Methods: This was a retrospective study of 8 patients with repaired tetralogy of fallot (TOF) who underwent bilateral branch PA valve implantation. Demographics, echocardiography, cardiac catheterization, and axial imaging data were reviewed. Variables were compared by a paired sample t-test. Results: All patients were adult sized (weight 43–99 kg) with oversized RV outflow tract not suitable for conventional transcatheter pulmonary valve implantation. Staged bare metal PA stenting followed by valve implantation (interval 3–5 months) was technically successful in 7 patients with one stent embolization. In another patient, proximal stent migration prevented placement of bilateral pulmonary valve stents. There were a total of 14 valved branch PA stents placed (Melody valve n = 9, Sapien XT n = 2, Sapien 3 n = 3). In the 7 patients undergoing successful branch pulmonary valve placement, at median follow up of 10 months (range 3 months to 6 years), 13 (93%) valves had none/trivial insufficiency on echocardiography. Prevalve and postvalve implantation cardiac magnetic resonance imaging in five patients showed significant reduction of indexed RV end-diastolic volume (152 ± 27 to 105 ± 15 mL/m 2 , P <.001). Conclusions: Transcatheter, bilateral branch PA valve implantation was technically feasible with satisfactory efficacy and safety in patients with repaired TOF, severe pulmonary insufficiency, and oversized RV outflow tracts. Elimination of pulmonary insufficiency with this method resulted in reduced RV end-diastolic volume. This approach can be offered as an alternative to surgery, particularly in patients considered high risk for standard surgical placement and who are not candidates for the newer self-expanding valve prosthesis for placement in RV outflow tracts larger than 30 mm diameter.

Original languageEnglish (US)
Pages (from-to)911-919
Number of pages9
JournalCatheterization and Cardiovascular Interventions
Volume91
Issue number5
DOIs
StatePublished - Apr 1 2018
Externally publishedYes

Keywords

  • CONP - congenital heart disease
  • PVD – pulmonary valve disease
  • PVT - percutaneous valve therapy
  • pediatrics
  • percutaneous intervention

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Bilateral branch pulmonary artery valve implantation in repaired tetralogy of fallot'. Together they form a unique fingerprint.

Cite this