Skip to main navigation Skip to search Skip to main content

Accuracy of low-dose prospectively gated axial coronary CT angiography for the assessment of coronary artery stenosis in patients with stable heart rate

  • Patricia Carrascosa
  • , Carlos Capuñay
  • , Alejandro Deviggiano
  • , Alejandro Goldsmit
  • , Carlos Tajer
  • , Marcelo Bettinotti
  • , Jorge Carrascosa
  • , Thomas B. Ivanc
  • , Arzhang Fallahi
  • , Mario J. García

Research output: Contribution to journal › Article › peer-review

Abstract

Background: Desirable methods for cardiac CT angiography would both reduce radiation exposure from cardiac CT angiography and preserve accuracy. Objectives: We assessed image quality, radiation dose, and diagnostic accuracy of a low-dose, prospectively gated axial cardiac CT angiography protocol for the evaluation of patients with suspected coronary artery disease (CAD). Methods: Fifty consecutive patients referred for diagnostic invasive coronary angiography (ICA) and with a stable heart rate < 60 beats/min after β-blocker administration were prospectively enrolled in a single center study. Subjects underwent CT angiography with a 64-row multidetector CT scanner with a prospectively gated axial imaging protocol. If the examination was determined to be nondiagnostic, then a retrospectively gated helical scan was performed. Two reviewers independently assessed image quality and the presence of significant coronary artery stenosis (>50%). Results: Prospectively gated CT angiography was successfully performed in 46 of 50 patients. Of 794 coronary segments, 777 were determined to be of diagnostic image quality. The overall patient-based sensitivity (95% CI), specificity, positive predictive value, negative predictive value, and accuracy for the diagnosis of significant coronary stenosis were 100% (87%-100%), 75% (53%-90%), 81% (64%-93%), 100% (81%-100%), and 88% (81%-95%), respectively. The mean effective radiation dose for CT angiography and ICA were 3.4 ± 0.4 mSv and 6.9 ± 0.8 mSv, respectively. Conclusions: Cardiac CT angiography performed in a prospectively gated axial mode with 64-row multidetector CT provides an accurate, low-dose alternative for the detection of CAD.

Original languageEnglish (US)
Pages (from-to)197-205
Number of pages9
JournalJournal of Cardiovascular Computed Tomography
Volume4
Issue number3
DOIs
StatePublished - May 2010

Keywords

  • Computed tomography
  • Coronary angiography
  • Coronary artery disease
  • Prospective ECG triggering
  • Radiation exposure

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Accuracy of low-dose prospectively gated axial coronary CT angiography for the assessment of coronary artery stenosis in patients with stable heart rate'. Together they form a unique fingerprint.

Cite this