Abstract
We proposed a method to reduce the volume of normal tissues irradiated by low doses in patients receiving CSI with RapidArc (RA) using Avoidance-Sector technique (RA+AS) and to compare its dosimetric implications with RA using full-arc (RA+FA) and 3D conformal technique (3DCRT). Four patients of CSI were retrospectively planned with 3DCRT, RA+FA, and RA+AS. Conformity-Index (CI), Homogeneity-Index (HI), and Paddick Gradient-Index (GI) were calculated. Quantitative evaluation was done using DVH analysis for PTVs and OARs. When compared with 3DCRT, GI, CI, and HI were favorable to RA based techniques. In comparison with 3DCRT the doses to OARs were lower with RA+AS with the difference being statistically significant in most instances. RA+AS significantly decreases the dose to OARs and their volumes receiving low doses in comparison with RA+FA and 3DCRT.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 488-491 |
| Number of pages | 4 |
| Journal | Journal of cancer research and therapeutics |
| Volume | 11 |
| Issue number | 2 |
| DOIs | |
| State | Published - Apr 1 2015 |
Keywords
- Avoidance sector technique in RapidArc
- RapidArc
- V5 in lung
- craniospinal irradiation
ASJC Scopus subject areas
- Oncology
- Radiology Nuclear Medicine and imaging
Fingerprint